NKR-CON-002
Neutral displacement valved connector
Keeps the access closed with no significant fluid movement in the catheter on disconnection. In two versions.
Use for up to 7 days or 200 connections

How it works
- 1
Connect
When a Luer syringe or administration set is attached, the septum opens and fluid flows.
- 2
Disconnect
On removal, the septum springs back and closes the access. The system stays closed until the next use.
Parts of the connector

- 1
Inlet with septum
Where the Luer syringe or administration set is attached.
- 2
Valve body
The split septum opens on connection and closes on disconnection.
- 3
Outlet with protective cap
Luer connection to the catheter, covered until use.
Product information
Technical characteristics
| Characteristic | High pressure | Low volume |
|---|---|---|
| Displacement type | Neutral | Neutral |
| Gravity flow rate (39.3 in head) | 150 mL/min | 120 mL/min |
| Priming volume | 0.075 mL | 0.045 mL |
| Reflux volume | Not stated | 0.01 mL |
| Pressure rating | Up to 400 psi | Up to 300 psi |
| Flow rate under pressure | 2,200 mL/min at 400 psi | 1,000 mL/min at 200 psi |
| Leak pressure | 450 psi | 320 psi |
| Functional activations | 200 over 7 days | 200 over 7 days |
| Latex-free | Yes | Yes |
| MRI compatible | Yes, per the manufacturer | Yes, per the manufacturer |
Materials
- Upper housing
- Tritan MX711 (copolyester) in the high pressure version; polycarbonate in the low volume version. Medical grade.
- Valve (septum)
- Silicone rubber, medical grade
- Lower housing
- Polycarbonate, medical grade
- Protective cap
- Polypropylene
Intended use and limitations
- Intended use
- Closing the access of the infusion system and allowing needle-free intravenous administration of fluids and drugs, and blood sampling.
- Used with
- Central venous catheter (CVC), PICC or peripheral venous catheter.
- User
- Healthcare professionals trained in intravenous therapy.
- Limitations
- Contraindicated in patients with venous access infarction or severe coagulation disorders. Use in hemodialysis and apheresis is not covered by the manufacturer's instructions. Do not use with needles.
- Replacement
- Every 7 days or 200 connections, whichever comes first.
Sterilization, shelf life and storage
- Sterilization
- Ethylene oxide. Sterile and non-pyrogenic.
- Shelf life
- 3 years from sterilization.
- Storage
- 0 °C to 40 °C, 30% to 85% relative humidity, away from direct sunlight.
- Use
- Single use. Do not reuse or resterilize.
Packaging
- Unit
- Sterile pouch, 80 × 32 mm
- Box
- 100 units, 210 × 110 × 70 mm
PDF in Portuguese. Instructions for use are sent on request. Contact
Contact Norkor
Quotations, samples and documentation for institutions and distributors.
contato@norkor.com.br